Cavitation is one of the most common causes of noise, vibration and early failure in centrifugal pumps. It can destroy an impeller in months. The good news is that it is usually preventable once the cause is understood.

What is pump cavitation?

Cavitation happens when the pressure at the pump inlet falls below the vapour pressure of the water. Small vapour bubbles form in the low-pressure zone at the eye of the impeller. As the bubbles move outward into higher pressure, they collapse violently. Each collapse sends a tiny shock wave into the metal surface.

Millions of these collapses wear away the impeller vanes, leaving a pitted, sponge-like surface. Cavitation also unbalances the impeller and damages seals and bearings.

Signs of cavitation

  • Noise: a crackling or rattling sound, often described as gravel or marbles passing through the pump
  • Vibration: higher than normal, often irregular
  • Unstable pressure: discharge pressure gauge flickers
  • Reduced performance: lower flow and head than the curve shows
  • Damage: pitting on the impeller, usually on the low-pressure side of the vanes near the inlet
  • Seal and bearing failures more frequent than expected

Common causes

Suction-side causes (classic cavitation)

  • Low water level in the suction tank, increasing suction lift
  • Long, small-diameter or complicated suction pipework with high friction losses
  • Blocked suction strainer or foot valve
  • Partly closed suction valve (suction valves should be fully open in operation)
  • Hot water, which has a higher vapour pressure. Roof tanks in UAE summers and hot water systems are both at risk.
  • Air entering the suction, through leaks or vortexing at a low tank outlet

Operating point causes

  • Running far to the right of the curve, at high flow, where NPSH required rises sharply. Common when a pump is oversized for head and the system lets it run out to high flow.
  • Running far to the left of the curve, at very low flow, which causes recirculation cavitation inside the impeller

How to prevent cavitation

  1. Check NPSH at the design stage. NPSH available must exceed NPSH required with a margin. See what is NPSH.
  2. Use flooded suction where possible, with the pump below the tank’s lowest water level.
  3. Design the suction pipe properly: short, one size larger than the pump inlet, with few bends, an eccentric reducer (flat on top), and a straight run before the pump.
  4. Keep strainers clean as part of routine maintenance.
  5. Set low level cut-outs in the tank so the pump stops before the level gets too low.
  6. Select pumps near their best efficiency point, and use a VFD to match the duty rather than letting the pump run out on its curve.
  7. Prevent vortexing at tank outlets with sufficient submergence or an anti-vortex plate.

Cavitation or something else?

Other problems can sound similar:

  • Air entrainment causes noise and loss of performance. Check for suction leaks.
  • Worn bearings make a grinding or whining noise that does not change with suction conditions.
  • Misalignment causes vibration at running speed.

A simple test: if partially closing the discharge valve (reducing flow) makes the noise stop, cavitation at high flow is the likely cause. See noisy pumps: causes and fixes.

Frequently asked questions

Can cavitation be heard?

Usually, yes. The sound is a distinctive rattle or crackle from the pump casing near the inlet.

Is cavitation dangerous?

It does not create a safety hazard by itself, but it damages the pump, reduces its performance and can lead to sudden failure.

Can a damaged impeller be repaired?

Light pitting can sometimes be repaired, but a heavily damaged impeller should be replaced, and the cause must be fixed or the new impeller will fail too.

Next step