A pressure switch is the simplest way to control a water pump automatically. It starts the pump when pressure falls and stops it when pressure rises. Set correctly with a pressure vessel, it gives reliable, low-cost control. Set incorrectly, it causes short cycling, low pressure and early pump failure.
How a pressure switch works
The switch has a diaphragm connected to the water line. Springs hold electrical contacts closed or open depending on the pressure acting on the diaphragm.
- Cut-in pressure: the pressure at which the switch closes and the pump starts.
- Cut-out pressure: the pressure at which the switch opens and the pump stops.
- Differential: the difference between the two, usually 1 to 1.5 bar on domestic switches.
Common factory settings are 1.4 bar cut-in and 2.8 bar cut-out (20/40 psi), or 2 bar and 3.5 bar (30/50 psi), but these vary by model.
The role of the pressure vessel
A pressure vessel (also called a pressure tank or expansion vessel) contains a rubber diaphragm or bladder with air on one side. When the pump runs, water enters the vessel and compresses the air. When a tap opens, the compressed air pushes water out until the pressure falls to the cut-in point.
Without a vessel, or with a vessel that has lost its air, the pump starts every time a tap opens and stops as soon as it closes. This rapid on-off operation is called short cycling.
Setting the vessel pre-charge
The air pre-charge in the vessel must be set with the vessel empty of water:
Pre-charge = cut-in pressure minus about 0.2 bar (or about 10% below cut-in).
Example: with cut-in at 2.0 bar, set the vessel pre-charge to about 1.8 bar.
To check it:
- Switch off and isolate the pump.
- Open a tap to drain the system pressure to zero.
- Check the air pressure at the vessel valve with a tyre gauge.
- Add or release air as needed.
Adjusting the switch
Most switches have two adjustment nuts under the cover:
- The large spring adjusts both cut-in and cut-out together, shifting the whole range up or down.
- The small spring adjusts the differential, mainly changing the cut-out.
Isolate the power before removing the cover. Make small adjustments, then test and observe the gauge. The cut-out pressure must stay within what the pump can actually produce, or the pump will never switch off.
Troubleshooting
Pump starts and stops rapidly (short cycling)
- Vessel has lost its air charge or the bladder has failed
- Differential is set too narrow
- Small leak in the system or a passing non-return valve
See pump short cycling: causes and fixes.
Pump does not switch off
- Cut-out set higher than the pump can reach
- Pump worn and no longer producing its original pressure
- Leak or open outlet in the system
- Pump has lost prime and is running without water
Pump does not start
- No power, tripped breaker or overload
- Switch contacts burnt or pitted
- Blocked sensing port on the switch
- Cut-in set too low
Low pressure at taps
- Settings too low
- Undersized pump
- Blocked strainer or filter
Pressure switch chatters
- Pressure fluctuations at the sensing point; mount the switch close to the vessel on a straight section
Pressure switch vs electronic pressure kit
Electronic pressure controllers (pressure kits) start the pump on pressure drop and stop it when flow stops. Many include dry-run protection and need only a small vessel or none. They suit homes where steady pressure and simple installation are preferred. For larger systems, variable speed control gives the most stable pressure.
Frequently asked questions
What pressure should my water pump switch be set to?
It depends on the pump and the building. For many homes, a cut-in of about 1.5 to 2 bar and a cut-out of about 3 to 3.5 bar works well, provided the pump can reach the cut-out pressure.
How often should I check the vessel pre-charge?
At least once a year, or whenever the pump starts short cycling.
Can I add a pressure switch to any pump?
Most surface pumps can be controlled by a pressure switch. Check the switch’s electrical rating against the pump motor, or use a contactor.
Next step